PARTS/FREQUENCY
BURN POT
SHELL AND TUBE HEAT EXCHANGER
COMBUSTION CHAMBER
REMOVABLE ASH PAN
T-SHAPED FITTING/ FLUE PIPE
A CLEAN BURN POT GUARANTEES CORRECT OPERATION!
BY KEEPING THE BURN POT AND ITS HOLES CONSTANTLY CLEAN AND FREE OF
COMBUSTION RESIDUE, EXCELLENT COMBUSTION IS GUARANTEED OVER TIME,
THUS PREVENTING ANY GENERATOR MALFUNCTIONS THAT MAY REQUIRE
TECHNICAL ASSISTANCE.
THE "EASY SETUP" FUNCTION IN THE USER MENU CAN BE USED TO ADAPT
COMBUSTION ON THE BASIS OF THE NEEDS DESCRIBED.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR
ROUTINE MAINTENANCE PERFORMED BY QUALIFIED TECHNICIANS
Routine maintenance must be performed at least once a year.
Given the generator uses pellets as solid fuel, it requires annual routine maintenance, which must be performed by a Quali ed technician,
using only original spare parts.
Failure to comply may jeopardise safety of the appliance and invalidate the warranty conditions.
By observing the cleaning schedule reserved to the user described in the use and maintenance manual, the generator will be guaranteed
correct combustion over time, thus preventing any faults and/or malfunctions which may require subsequent technical assistance. Requests
for routine maintenance are not covered by the warranty.
GASKETS: PELLET HOPPER LID, DOOR, ASH DRAWER AND BURN POT
The gaskets ensure the proper sealing of the stove and therefore its proper operation.
They must be periodically checked and immediately replaced if worn or damaged.
These operations must be carried out by a quali ed technician.
CONNECTION TO THE FLUE
Annually, or in any case each time the ue pipe needs to be vacuumed and cleaned. If there are horizontal sections, the residue must be
removed to prevent it from obstructing the ow of fumes.
SHUT DOWN END OF SEASON
At the end of each season, before turning the stove o , it is advisable to completely empty the pellet hopper, removing any pellet residue and
dust with a vacuum cleaner.
Furthermore, please disconnect the generator from the mains electricity and, for greater safety especially in the presence of children,
remove the power cord.
Routine maintenance must be performed at least once a year.
EVERY 2 DAYS
VISIT THE WEBSITE:
WWW.LANORDICA-EXTRAFLAME.COM
ENGLISH
X
X
X
EVERY YEAR
X
X
BURN POT HOLES
67