SETTINGS
•
DATE TIME
•
LANGUAGE
•
DEGREES
UPDATE
This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. If set to OFF, the display backlighting is set
to maximum brightness and turns o after a 60 second delay.
The backlighting can be turned on again by pressing any key or if the stove is in alarm status.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and con rm by pressing key 6.
Keep pressing key 3 until DISPLAY appears and con rm by pressing key 6.
Use keys 4-5 to set the desired intensity.
Press key 6 to con rm and key 1 to scroll back through the menus until the initial page.
STAND BY
The STAND BY function, if enabled, is used when stove switch-o is to be controlled by means of an additional thermostat.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and con rm by pressing key 6.
Keep pressing key 3 until STAND BY appears and con rm by pressing key 6.
Use keys 4-5 to enable (ON) / disable (OFF).
Press key 6 to con rm and key 1 to scroll back through the menus until the initial page.
STAND BY FUNCTION SET TO ON
If the STAND BY function is enabled (ON), if the ambient temperature exceeds the SET THERMOSTAT + DELTA T value, the stove switches
o after a preset factory delay, and STAND BY will be displayed on the screen.
When the ambient temperature is less than SET THERMOSTAT DELTA T and after a certain cooling time, the stove ignites again.
STAND BY FUNCTION SET TO OFF FACTORY SETTING
When the STAND BY function is not enabled (OFF), if the stove exceeds the set ambient temperature, it will switch to the minimum power
level, modulating and displaying MODULATION on the screen. When the ambient temperature is lower than the SET THERMOSTAT the
stove will resume operation at the set power and WORK will be displayed on the screen.
OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL
STAND BY FUNCTION SET TO OFF FACTORY SETTING
If the Stand-by function is not enabled (OFF), when the stove reaches the ambient temperature set on the additional thermostat (open
contact), it will switch to the minimum power level and MODULATION will be displayed on the screen. When the ambient temperature is
lower than the set value on the additional thermostat (closed contact), the stove will resume operation at the set power, and WORK will be
displayed on the screen.
STAND BY FUNCTION SET TO ON
If the STAND-BY function is enabled (ON), when the ambient temperature set on the additional thermostat is reached (open contact), the
stove will switch o after a preset factory delay period, and STAND BY will be displayed on the screen.
When the ambient temperature is less than the set temperature on the additional thermostat (closed contact), and after a certain cooling
time, the stove ignites again.
62
FOR CORRECT OPERATION, THE SET THERMOSTAT MUST BE SET TO LOW TA.
> SEE CHAPTER ON ADDITIONAL THERMOSTAT SETTINGS
SEE CHAPTER: FIRST IGNITION SETTINGS
ENGLISH