TECHNICAL DATA
See tables and "Conne ction chart" at the back of
the manual.
SAFETY DEVICES
Although the appliance is complete with all safety
devices, during installation and connection addi-
tional devices must be added if necessary to com-
ply with the relevant legal requirements.
A)Gas supply tap: for turning the connection to the
gas supply line on and off.
B)Safety thermocouple: cuts out the gas supply if the
flame goes out.
C)Safety thermostat: cuts off the gas supply in case of
overheating.
Caution - warning
Make a daily check that the safety devices are
properly installed and in good working order.
SAFETY AND INFORMATION SIGNS
The illustration shows the position of the signs pro-
vided.
A)Nameplate with manufacturer and appliance
data.
B)General hazard: read the manual carefully before
carrying out any procedure.
C)General hazard: when washing the appliance do
not point pressurised water jets at internal parts.
D)General hazard: dry operation is forbidden.
E)General hazard: all r elevant regulations must be
complied with. "Install in compliance with the rele-
vant regulations and use in well ventilated premises
only".
F) General hazard: all r elevant regulations must be
complied with. "No liability is accepted in case of fail-
ure to comply with the installation and comm ission-
ing instructions".
G)CE marking: indicates that the appliance is compli-
ant with the relevant norms.
C
C
D
B
- 5 -
B
A
IDM-39615800300.tif
E
F
A
IDM-39615800400.tif
IT
GB
DE
G
FR
ES
English