To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the scr ews (B) and remo ve the control
panel (C).
4 - Undo the screw (D) of the pressure connection.
5 - Connect the pressure gauge (E) to the pressure
test point (F).
6 - Fill the well with water and turn the gas supply
tap back on.
7 - Light the burner and turn the knob to the full
flame setting (see page 8), then check that the
pressure reading complies with the values in
the table (see back of manual).
8 - Switch off the burner, turn off the gas supply tap
and disconnect the pressure gauge.
9 - Restore the initial conditions a fter completing
the operation.
IT
The appliance has been tested be fore being put
into service.
GB
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and ma lfunctions which might occur dur ing
DE
use.
FR
FR
Faults
Smell of gas
ES
The pilot light does not ignite
English
CHECKING GAS PRESSURE
TROUBLESHOOTING
Occasional leak because flame
The spark ignition devices are not
Air in pipelines due to long period
A
B
FAULT
The user ca n solve some of these problems him-
self, but for others specific technical knowledge or
skill is req uired, and so they must only be carr ied
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
Causes
has gone out
working
out of use
- 12 -
E
B
D
C
Remedies
Turn off the gas supply tap and
ventilate the room
Check that the ignition devices
are in good working order
Light by hand with a naked light
Important
Contact the after-sales
service
Make more attempts to light the
flame
F
IDM-39615801100.tif
6