WATER CONNECTION
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the water supply to be cut off when
necessary. Easily accessible filters must be fitted
downstream of the tap.
Caution - warning
The appliance must be supplied with drinking
water having the characteristics shown in the
table.
Description
Pressure
pH
Conductivity
Hardness
Salt and metallic ion con-
tent
Chlorides
Sulphates
Iron
Copper
Manganese
IT
GB
CONVERSION OF GAS SUPPLY
The constructor has tested the appliance with its
DE
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
FR
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
ES
2 - Change the burner nozzle (see page 21).
3 - Change the pilot light nozzle (see page 22).
4 - Adjust the minimum settings of the gas control
valves of the burners (see page 20).
English
Value
200÷450 kPa (2÷ 4,5 bar)
7÷7.5
< 200 mS/cm
9÷13°f (5÷7°d, 6.3÷8.8°e,
90÷125 ppm)
< 30 mg/l
< 40 mg/l
< 0,1 mg/l
< 0.05 mg/l
< 0,05 mg/l
- 18 -