• fit fuses to protect the power supply line, rated as indicated on the general electrical
system diagram enclosed with this manual;
• provide a suitable earthing system on the workshop mains line.
- To prevent unauthorised use of the machine, always disconnect the mains plug when
the machine is out of use (switched off) for lengthy periods.
- If the machine is connected directly to the power supply by means of the main electrical
panel without the use of a plug, a key-switch or device with padlock fixture must be
provided to restrict use of the machine to authorised personnel only.
WARNING
A good earth connection is essential for proper operation of the machine.
NEVER connect the earth wire to a gas or water pipe, telephone wire or any other
unsuitable objects.
Check that the pressure and flow-rate provided by the compressed air system are com-
patible with those required for proper operation of the machine - see "Technical Data"
section. For correct operation of the machine the compressed air supply line must provide
a pressure range from no less than 8 bar to no more than 16 bar.
Make the connection to the compressed air system by means of a supply line connected
to the intake of the air treatment unit on the side of the base of the machine - A fig. 5b.
Check that the Lubricator unit B fig. 5b contains air lubricating oil; top up if necessary.
Use SAE20 oil.
The customer must provide an air cut-off valve upstream of the air treatment and regulator
device supplied with the machine B fig. 5a.
ATTENZIONE
The machine is equipped with a pressure regula-
tor set at 10 bar (standard use of the machine).
When working on weak rims (i.e. with central
well with thin, projecting edges - see side), we
recommend to use the universal flange / flange
for close centre rims.
Artiglio Master operator's manual
EN
45