2.2 Rear control panel

* I1: Start switch
It is provided with two positions: "O" off; "I" on.
* J6 : Wire feeder WF104 connector.
Provided with contacts for fibre optics, for the connection of
the control cable bundle for the wire feeder WF104.

2.2.1 Wire feeder WF104

The wire feeder WF104 is the movable part of a complete
MIG/MAG welding plant for the
Genesis GSM. The WF104 must
be connected to the generator
by means of a cable bundle
available in different lengths.
The unit is extremely compact,
with the wire spoof compart-
ment completely protected.
The unit is provided with a
120W gearmotor and the wire
is fed by 4 rollers.
The microprocessor controls
the wire speed through the
signal of an encoder positioned
on the motor; it also controls all
the information coming from the generator through the cable
bundle. Upon request the WF104 can be equipped with the
connector and electric p.c. board for the use of PUSH-PULL
torches.
Upon request it can also be provided with a kit of accessories
(rollers and wire-guide bushing in teflon) for welding with alu-
minium wires and wires with core.
Positioning on the generator is ensured by the apposite support
that guarantees 360° rotation.
2.2.2 Remote control RC07 for MIG/MAG welding
It can be installed on the wire feeder WF104.
It is provided with two knobs that
make it possible to remotely adjust
the wire speed and the welding arc
length. The upper knob varies the
wire speed/thickness/current from a
minimum of "1" to a maximum of
"10".
The other knob scale is 5-0-5:
- "0" corresponds to the recommen-
ded arc length;
- "5" on the left corresponds to a very short arc;
- "5" on the right corresponds to a very long arc.
The actual value set is shown on D1.
18
Fig. 2
- Activation of the remote control mode is automa-
tic by connecting the control itself (PLUG and PLAY).
- To de-activate the remote control, turn both poten-
tiometers fully anti-clockwise or remove the control.

2.3 Technical specifications

GENESIS 282
Power supply
voltage
(50/60Hz)
3x400V ±15%
Max. absorbed
power
Max. absorbed
current
Delayed fuses
500V
Efficiency
Power factor
MMA/TIG/MIG 40°C
(x= 60%) 280A
welding current
(x=100%) 220A
MMA/TIG/MIG 25°C
(x=100%) 280A
welding current
Adjustment range
DC MMA
6A/20V-280A/31.2V
DC TIG
6A/10V-280A/21.2V
DC MIG
15A/15V-280A/28V
No-load voltage
Protection degree
Insulation class
Construction
standards
EN60974-10
Data at 40°C ambient temperature
Dimensions and mass
Fig. 3
Trolley
type
A
GT23
930
Fig. 4
GENESIS 352
PME
PME
3x400V ±15%
10.1kW
13.7kW
21A
27.5A
20A
30A
0.87
0.87
0.69
0.72
(x= 60%) 350A
(x=100%) 270A
(x=100%) 350A
6A/20V-350A/34V
6A/10V-350A/24V
15A/15V-350A/31.5V
81V
81V
IP23S
IP23S
H
H
EN60974-1
EN60974-1
EN60974-5
EN60974-5
EN60974-10
Dimensions in mm
B
C
D
1000
610
1400
GENESIS 503
PME
3x400V ±15%
22.9kW
42.9A
40A
0.87
0.77
(x= 50%) 500A
(x=100%) 400A
(x=100%) 500A
6A/20V-500A/40V
6A/10V-500A/30V
15A/15V-500A/39V
79V
IP23S
H
EN60974-1
EN60974-5
EN60974-10
Mass
Kg
29