8 WF104 GENERAL PRECAUTIONS

The mobile units are powered exclusively at low voltage 42 Vac,
in compliance with strict international regulations.
You are nevertheless advised to observe the elementary precau-
tions illustrated in detail in the power source operating manual.
Before carrying out any work, replacement or
repair of parts, ensure that the power source is
disconnected from the power supply line.

8.1 Front control panels

* T1:
Permits bleeding of the air in the gas circuit pipes.
* T2:
Permits manual wire feed (useful for passing the wire
along the torch sheath during preparation operations).
* A5 water fitting: it must be connected to the MIG torch
delivery pipe (generally blue), if the latter is water-cooled.
* A6 water fitting: it must be connected to the MIG torch
return pipe (generally red), if the latter is water-cooled.
* Connector J2: present on the trolley only as an optional (see
accessory kit). Any Push-Pull torch connector must be con-
nected to it; this torch is provided with wire tensioning motor,
and is particularly useful for welding aluminium.
* J1: remote control connector.
Fig. 7
Fig. 8

8.2 Rear control panel

* Socket D2: the power cable of the cable bundle coming from
the power source must be connected to this socket.
* Conector J3: the 5+2-pole connector of the cable bundle com-
ing from the power source must be connected to this connector.
* A3 water fitting: the pipe bundle delivery pipe must be con-
nected (blue).
* A4 water fitting: the pipe bundle return pipe must be con-
nected (red).
* A1: Gas fitting.

8.3 Technical specifications

Diameter of wire workable
Speed of wire feed
Power of geared motor
Wire feed button
Gas discharge button
Remote control
Connector for Push-Pull torch
Steel rollers
Teflon rollers
Protection rating
Insulation class
Weight
Dimensions (HxWxD)
Data at 40°C ambient temperature
Fig. 9
WF104
0.8-1.0/1.2-1.6
0.8-1.0/1.2-1.6 aluminium
1.0-1.2-1.4-1.6 cored
1-22 m/min.
120W
optional
optional
IP23S
18 Kg.
435x220x600 mm
yes
yes
yes
yes
H
21