EN
7.0 BATTERY
CPWplus standard unit can be operated from 6x AA batteries,
if desired.
CPWplus-W, CPWplus-M and CPWplus-L scales have an
internal rechargeable battery. When the battery needs
charging a symbol on the display will turn on. The battery
should be charged when the symbol is on.
To charge the battery, connect the power supply module to
the rear of the indicator and apply power. The scale need not
be turned on. The indicator must be attached to the base
for the batteries to charge.
The battery should be charged for 12 hours for full capacity.
The battery life is approximately 60 hours.
Internal rechargeable batteries can be changed, but please
first ask for technical support from your dealer or the
manufacturer. Replacement batteries should be type BT-
6M1.3AC (6V1.3AH) or direct equivalent.
NOTE: When you turn off the scale by pressing the ON/OFF key,
the power is not completely isolated. You should disconnect the
power supply if it is not going to be used for an extended period.
8.0 BACKLIGHT
The backlight for the LCD can be set by the user to always off, always on
or automatic (on only when the scale is in use or a key is pressed). See
setting of the parameter in section 13.1.2.
The backlight should be set to OFF when batteries are used to prolong
the battery life.
9.0 AUTO POWER OFF
The auto power off can be set by the user to disable the feature or to a
pre-set time interval. See setting of the parameter in section 13.1.1.
© Adam Equipment Company 2014
9
9009RevD2-March 2017