Electric Diagram for PWLD3000Ai12/24V - PWLD4000A12V - PWLD600012V.
1) Connect the red short cable from the solenoid to the red terminal from the motor.
2) Connect the black short cable from the solenoid to the black terminal from the motor.
3) Connect the A cable from the remote control to batteries's negative terminal (-).
4) Connect the B cable from the remote control to batteries's positive terminal (+).
Connecting the Remote Control
1) Connect the red cable to ground.
2) Connect the black cable to black terminal
3) Connect the green cable to green terminal from the solenoid.
When you are satisfied that all other connections are correctly installed connect the battery leads to the battery (via an isolator switch
and overload cut out if being used).
Control
Rojo sin terminal
conectar a masa
Fig. 8
21