Product Life Cycle Handling; Transport; Packaging; Storage - Kollmorgen AKD Serie Manual De Instrucciones

Ocultar thumbs Ver también para AKD Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 133
AKD Product Safety Guide | 1   English

1.3 Product life cycle handling

1.3.1 Transport

Transport the AKD in accordance with IEC 61800-2 as follows:
The drives contain electro-statically sensitive components that can be damaged by incor-
rect handling. Electro-statically discharge yourself before touching the drive. Avoid contact
with highly insulating materials, such as artificial fabrics and plastic films. Place the drive on
a conductive surface.
If the packaging is damaged, check the unit for visible damage. Inform the shipper and the
manufacturer of any damage to the package or product.

1.3.2 Packaging

The AKD packaging consists of recyclable cardboard with inserts and a label on the outside
of the box.
Model
AKD-x00306 , -x00606
AKD-x01206
AKD-x02406
AKD-x00307, -x00607, -x01207 158 x 394 x 292
AKD-x02407
AKD-x04807

1.3.3 Storage

Store the AKD in accordance with IEC 61800-2 as follows:
10
Kollmorgen | kdn.kollmorgen.com | October 2018
Transport only by qualified personnel in the manufacturer's original recyclable packaging.
Avoid shocks while transporting.
Store at or below maximum stacking height:
AKD-x00306 to x00606 models: 8 cartons,
AKD-x01206, x02406, x00307 to x02407 models: 6 cartons,
AKD-x04807 models: 3 cartons.
Transport only within specified temperature ranges:
-25 to +70 °C, max. rate of change 20 K/hour, class 2K3.
Transport only within specified humidity:
max. 95% relative humidity, no condensation, class 2K3.
Store only in the manufacturer's original recyclable packaging.
Store at or below maximum stacking height:
AKD-x00306 to x00606 models: 8 cartons,
AKD-x01206, x02406, x00307 to x02407 models: 6 cartons,
AKD-x04807 models: 3 cartons.
Store only within specified temperature ranges: -25 to +55 °C, max.rate of change
20 K/hour, class 1K4.
Storage only within specified humidity: 5 to 95% relative humidity, no condensation, class
1K3.
Store in accordance with the following duration requirements:
Less than 1 year: without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the
drive. Re-forming procedures are described in the Kollmorgen Developer Network
(Forming).
Package
Total Weight (kg)
(mm) HxWxL
AKD-B, -P, -T
113 x 250 x 222
1.7
158 x 394 x 292
3.4
158 x 394 x 292
4.3
158 x 394 x 292
6.7
390 x 600 x 400
15.3
Total Weight (kg)
AKD-M
1.9
3.6
5
5.2
4.5
6.9
15.5

Publicidad