SYSTEM DIAGRAMS
The system has 2 circulators:
Boiler Circulator enabling buffer loading. The circulator activates once the boiler temperature
of 50°C is reached and will always work until the differential between the boiler temperature
and buffer temperature reach 5°C.
PI System circulator allows management of heating system controlled by buffer. The circulator
activates if the buffer temperature is over 50°C.
ANTI-CONDENSATE VALVE ASSEMBLY
CIRCULA-
TOR
BOILER
To connect the boiler circulator see the connections diagram on page 73.
The diagram includes use of accessories available on the EDILKAMIN pricelist.
Loose parts are also available from local dealers (exchanger, valves, etc.),
INSTALLATION
SAFETY VALVE
DEAERATION AND GAUGE
EXPANSION
CHAMBER
VALVE FOR
ANTI-CONDENSATE
50°C
BUFFER PROBE
P1
CIRCULATOR
SYSTEM
BUFFER
- 61
-