POSSIBLE TROUBLESHOOTING

• Attention, all repairs must only be carried out by the Technical Support Centre authorised
by EDILKAMIN (TSC)
• Only original spare parts must be used.
• The manufacturer cannot be held in any way liable and the warranty expires if all the op-
erations described below are not complied with and carried out correctly.
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION INSTRUCTIONS AND SOLUTIONS
SIGNALLING
Er01
Water high temperature block
Activates if the water reading
reads a temperature over
90°C
Er04
Water excess temperature error
Water temperature too high in
boiler
Er05
Smoke high temperature block
switch off due to excessive smoke
temperature
Er11
Internal clock error
Er15
No mains block
(not a defect of the boiler).
No electrical power for more than
50 minutes.
Er16
Error RS485
Communication error between the
control board and the display
Er23
Boiler or buffer temperature
probes error
PROBLEM
probe
- 79
-
ACTIONS
Check the circulator is working properly
(TSC)
Check the plumbing (TSC)
Re-activate the reset thermostat (User)
Check the plumbing (TSC)
Check the smoke probe (TSC)
Clean the exchangers (TSC)
Excessive temperature of smoke can
depend on: smoke extraction anomaly,
blocked channel, improper
installation, no air intake in
premises(TSC).
Replace the battery on the electronic
board (TSC)
Remember it is a part subject to regular
wear and therefore not covered by
warranty.
Check the electrical connection and
drops in voltage (User)
Cut power from the boiler, wait a few
minutes and then power again (User)
Check the probes and their connections
(TSC).