INSTRUCTIONS FOR USE
The boiler is equipped with the following safety devices:
• SAFETY EXCHANGER
Connected to a thermal relief valve, it keeps the temperature under 110°C in the event of an emer-
gency.
• WATER BULB THERMOSTAT
Checks the temperature of the water inside the boiler. If the temperature exceeds the limit of 90°C
it shuts off the fan and stops combustion.
• WATER TEMPERATURE PROBE
If the temperature reaches the thermostat value, the boiler switches off or goes into stand-by.
• NO SWITCH ON
If during the switch-on phase the wood-burning boiler does not reach the smoke temperature of at
least 60°C in 40 minutes the boiler turns Off.
• ELECTRICAL SAFETY
The boiler is equipped with a fuse to protect the electronics.
RE-ACTIVATION OF THE RESET THERMOSTAT
To re-activate the reset thermostat, unscrew the black hood and fully press the small cylinder until
you hear a release click.
To intervene on the water bulb safety thermostat, contact the Technical Support Centre authorised
by EDILKAMIN (TSC) to check the cause.
- 74
-