Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the boiler to function correctly.
Any problems resulting from lack of maintenance will immediately void the warranty.
When cleaning is necessary, the message "Clean - exchanger" will appear on the panel if further cleaning is necessary.
N.B.
- Any unauthorised modifi cation is forbidden
- Use spare parts recommended by the manufacturer
- The use of counterfeit parts results in the guarantee becoming null and void
DAILY MAINTENANCE
Operations must be performed when the boiler is off, cold and unplugged from the power supply.
Cleaning should be carried out with the aid of a vacuum cleaner (see optional page. 43), the whole procedure takes up a few minutes.
• Suction clean the door
(1 - fi g. A).
• Open the door, remove the combustion chamber (2 - fi g. B) and empty the residue out into the ash pan.
• Scrap the combustion chamber with the spatula provided, removing any obstructions in the openings.
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Take out and empty the ash (3 - fi g B) pan into a fi reproof container (the ash may still contain hot parts and/or embers).
• Vacuum clean the inside of the fi replace, the fi re surface, the compartment around the chamber where ash falls, and the ash pan.
• Vacuum the combustion chamber holder, clean the edges where the combustion chamber is lodged into its seat.
• Vacuum around the electrical element
ACTIVATE THE BRUSHES TO CLEAN THE EXCHANGERS (*), ALSO WHEN THE STOVE IS LIT, US¬ING THE
GLOVE PROVIDED;
- Shake the cleaning handle positioned under the pellet loading cover (5 - fi g. D).
NEVER SUCTION HOT ASH, as this could damage the suction device and possibly cause a fi re.
ATTENTION: MAKE SURE THE ASH PAN IS CORRECTLY POSITIONED IN ITS HOUSING (3 fi g. B)
1
fi g. A
4
fi g. C
MAINTENANCE
(4 - fi g. C).
fi g. B
- 38
-
2
3
fi g. D
5