To be integrated with a complete reading of the technical specifi cations
Positioning and installation
•
Commissioning done by an approved CAT that issued the guarantee
•
Air vent in the room
•
Only the boiler outlet passes through the smoke channel/chimney fl ue
•
Features of the smoke channel (stretch of duct connecting the boiler to the fl ue/chimney):
a maximum of 3 curves
a maximum of 2 horizontal metres
•
The exhaust pipes are made of suitable material (recommended: stainless steel)
•
When using any fl ammable materials (e.g. wood), all precautions have been taken to prevent a fi re hazard
•
The heating capacity has been appropriately assessed considering radiator effi ciency:
•
The hydraulic system has been declared to be compliant with the Ministerial Decree 37 ex Law No. 46/90 by a qualifi ed
technician.
Use
•
Good quality, dry wood pellets are used (diameter 6/8 mm) (maximum permissible humidity 8%).
•
The chimney pot and ash compartment are clean and well positioned.
•
The cleaning rods are moved every day.
•
The exchanger tubes and internal parts of the hearth are clean.
•
The smoke extract duct is clean.
•
The bleeding process has been applied to the hydraulic system.
•
The pressure (shown on the pressure gauge) is at least 1,5 bar.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
TELEP HONE COMBINER FOR RE MOTE IGNITION
The boiler can be ignited remotely by asking the DEALER to connect the telephone combiner to the serial port behind the boiler
via the optional cable (code 640560).
DOMOKLIMA GRAPHIC CONSOLE
A graphic display which shows the boiler's state and any changes in the operating parameters.
CHECK LIST
OPTIONAL
CLEANING ACCESSORIES
Ash vacuum cleaner without motor
(code 275400)
Used for cleaning the hearth
- 43
-