• If <PG> key is pressed, presetting to be modified can be entered.
• The preset values can be modified by using <+> and <-> keys.
• The value is programmed if <PG> key is pressed again. The word "PRG" appears on the display.
See paragraph "Programming Example".
NOTES:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
Pressing <-> with the display turned off means an impulse of P.P.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Braking value of motor 1. The values indicate the brake percentage of
tsm1
the gate leaf (25%-50%-75%-100%) compared to the total opening/
closing.
Braking value of motor 2. The values indicate the braking percentage
tsm2
of the gate leaf (25%-50%-75%-100%) compared to the total opening/
closing.
Operating time of pedestrian gate leaf
Values which can be preset are:
TPED
25: 25% opening
50: 50% opening
100: 100% opening
PMo1
The torque applied to motor 1 during the opening phase is adjusted.*
PMC1
The torque applied to motor 1 during the closing phase is adjusted.*
PMo2
The torque applied to motor 2 during the opening phase is adjusted.*
PMc2
The torque applied to motor 2 during the closing phase is adjusted.*
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
It regulates the motor 1 speed during braking. The value is expressed in
SLD1
percentage with respect to normal operating speed.
It regulates the motor 2 speed during braking. The value is expressed in
SLD2
percentage with respect to normal operating speed.
The torque applied to motor 1 during braking in the opening phase is ad-
Pso1
justed *
The torque applied to motor 1 during braking in the closing phase is ad-
Psc1
justed *
The torque applied to motor 2 during braking in the opening phase is ad-
Pso2
justed *
The torque applied to motor 2 during braking in the closing phase is ad-
Psc2
justed *
It adjusts the operating time of the service light when the "Service Light"
TLS
logics is preset to ON and the "2nd radio channel" logics is preset to
OFF
* WARNING: An incorrect setting of these parameters may result in an hazard. Comply with regulations in force!
To check the torque applied to the various phases of the operation, proceed as follows:
With switched-off display and moving gate leaves, press and keep the <+> key pressed
Two figures separated by a dot are displayed (e.g. 52.55), the first two figures indicate the torque applied to motor 1, while the
last two the torque applied to motor 2.
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
PARAMETERS (PAR)
FUNCTION
MEMO
MIN-MAX-(Default)
1-240-(40s)
25-100-(50)
25-100-(50)
25-100-(100)
1-99-(20%)
1-99-(20%)
1-99-(20%)
1-99-(20%)
0-15-(2s)
0-40-(3s)
40-99 (50)
40-99 (50)
1-99-(20%)
1-99-(20%)
1-99-(20%)
1-99-(20%)
2s-180s-(60s)
13