Beninca CP.BN Manual De Instrucciones página 14

Ocultar thumbs Ver también para CP.BN:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter
IbL
impulse has no effect during the opening phase.
Off: condominium function disabled.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the
SCL
intervention of the photocell causes automatic closing after 3 s. Active only
with TCA:ON.
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the
transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
The "service light" function is enabled or disabled on terminals (9-10)
On: output, enabled as "Service light". This output is activated at the beginning
SERL
of each operation and remains activated for the time preset by parameter TLS.
Off: output, enabled as "Open gate light".
This function is not enabled if the "2°Ch radio" logics is preset to ON.
The second radio channel is enabled or disabled on terminals (9-10).
On: "2
radio channel" output is enabled.
nd
Off: "2
radio channel" output is disabled. The output to terminals is activated
nd
2ch
as "Service light" if SERL=On, or as SCA if SERL=Off.
If this function is preset to On, any presetting of the SERL logics will be ig-
nored.
The OPEN Input mode is preset.
On: OPEN Input, with CLOCK function.
To be used as connection to timer for timed opening/closing. (Closed contact:
CLOC
gate open. Open contact: normal operation).
Off: OPEN input, with OPEN function.
This function is activated only if the OPCL logics=ON
The Step-by-Step and Pedestrian input modes is selected.
On: Input to terminal 18 activated as OPEN. Input to terminal 17 is activated
OPCL
as Closed.
Off: Input to terminal 18 activated as Step-by-Step. Input to terminal 17 acti-
vated as Pedestrian.
The total reverse movement is enabled or disabled when the amperometric
sensor is triggered.
INVC
On: total reversion is enabled
Off: total reversion is disabled. The control unit controls a 2sec reversion and
then locks the gate leaves.
Start control signal to motors:
MINV
On: motor 2 starts first in the opening phase.
Off: motor 1 starts first in the opening phase.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters
(self-learning and Dip Switch).
The remote storage of the radio transmitter codes is enabled or disabled (see
par. REMOTE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
14
LOGICS (LOG)
FUNCTION
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
OFF
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(ON)

Publicidad

Tabla de contenido
loading

Tabla de contenido