GENERAL NOTES
The smoke discharge and plumbing connections must
be carried out by quali ed personnel who can issue an
installation declaration of conformity complying with
national law.
In Italy it is necessary to refer to the standard declaration
of conformity conforming to Ministerial Decree 37/2008
(pursuant to Law 46/1990) and standards UNI 10683/2012
and UNI 10412-2/2009.
In the case of installation in a multiple-tenancy building,
contact the building manager before installation.
In France, it is necessary to refer to Decree 2008-1231.
VERIFY COMPATIBILITY WITH OTHER DEVI-
CES
In Italy the boiler MUST NOT be installed in the same
space as type B gas heating equipment (e.g. gas boilers,
stoves, and equipment served by an extraction hood - ref.
UNI 10683 and 7129).
In general, the boiler could create low pressure in the
room, affecting the operation of such appliances or being
affected by them.
VERIFY THE POWER SUPPLY
CONNECTION
(the plug must be accessible)
The boiler is supplied with a power cable that is to be
connected to a 230V 50 Hz socket, preferably fi tted with a
magnetothermic switch.
The electrical system must comply with the law; particu-
larly verify the effi ciency of the earthing system.
The power line must have a suitable cross-section for the
boiler power.
An inadequate earthing system can cause anomalies for
which Edilkamin cannot be held liable.
In case of problems with the electrical grid, consult an
electrician to evaluate the installation of a sine-wave UPS
of at least 800 Va.
Power variations greater than 10% can cause problems for
the product.
AIR INLET
(to be mandatorily implemented)
The room where the boiler is located must have an air
intake with cross section of at least 80cm
nishment
of the air consumed by combustion.

INSTALLATION

POSITIONING AND DISTANCES FOR FIRE SAFE-
TY
For correct operation the boiler must be level.
Check the load-bearing capacity of the fl oor.
The boiler-stove must be installed in compliance with the
following safety conditions:
- fl ammability items must be kept at a minimum distance
of 10 cm from the sides and back of the boiler
- highly fl ammable items must be kept at a minimum
distance of 80 cm if placed in front of the boiler
- if the boiler is installed on a fl ammable fl oor, a sheet of
heat insulating material must be placed between the boiler-
stove and the fl oor, which protrudes by at least 20 cm at
the sides and 40 cm at the front.
Flammable objects must not be placed above the boiler or
at a distance that is any less than the stipulated safety di-
stances. If connected to wooden walls or other fl ammable
materials, the smoke exhaust pipe must be appropriately
insulated with ceramic fi bre or other similar material.