To be integrated with a complete reading of the technical speci cations
Positioning and installation
•
Commissioning done by an approved CAT that issued the guarantee
•
Air vent in the room
•
Only the boiler-stove outlet passes through the smoke channel/chimney fl ue
•
Features of the smoke channel (stretch of duct connecting the boiler-stove to the fl ue/chimney):
a maximum of 3 curves
a maximum of 2 horizontal metres
•
The exhaust pipes are made of suitable material (recommended: stainless steel)
•
When using any fl ammable materials (e.g. wood), all precautions have been taken to prevent a fi re hazard
•
The heating capacity has been appropriately assessed considering radiator effi ciency:
•
The plumbing system is declared conforming the laws of the country (such as, in Italy, to Ministerial Decree
37, formerly
Law 46/1990) by a qualifi ed technician.
Use
•
Good quality, dry wood pellets are used
•
The burner and ash tray must be clean and correctly positioned
•
The door must be securely closed
•
The burner must be properly inserted in its seat
•
The smoke extract duct is clean.
•
The bleeding process has been applied to the hydraulic system.
•
The pressure (shown on the pressure gauge) is at least 1,5 bar.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.