WARNINGS
7.1
The equipment must not be used with any of its parts disassembled: before using the
equipment make sure that all its components are properly in place.
To ensure that work is done in absolute safety always make sure that you follow the
described procedures with caution.
To provide greater clarity the numbers given in the diagrams in the following
paragraphs correspond exactly to the numbering in Chapter 3 in the "Equipment
Description" section.
SAFETY SYSTEMS
7.2
To ensure optimum working reliability, Zhermack employs only top quality materials and components for
the manufacture of the equipment. The equipment is also thoroughly tested before delivery.
All materials are of only the highest quality and are checked on arrival at our plant, during
storage and when they are used so as to guarantee a product that is free from damage,
deterioration and/or malfunctions.
In particular, the steam generators, in addition to the safety fuse and safety valve, have:
1. On the VAP 6A.
Automatic pump shutdown if the pump overheats because of high pressure or lack of water.
To reset the pump proceed as follows:
- turn the element switch to OFF (4);
- switch off the machine via the main switch (3) and remove the plug from the power socket;
- let the pump cool down, operation will resume automatically as soon as the temperature falls
back within the safe operating limits.
2. On the VAP 6 and VAP 6A.
Internal safety pressure switch, which shuts down the machine if working pressure exceeds 8 bar; in this
event the overpressure warning light comes on. To reset the machine proceed as follows:
- release pressure via the gun until it drops to 1 bar;
- turn the element switch to OFF (4);
- switch off the machine via the main switch;
- switch the machine back on.
150 of 328
CHAPTER 7: USING THE EQUIPMENT
MAINTENANCE AND USE MANUAL
EN
VAP 6 / 6A - AD 8