5.1.5

Structure-borne and airborne noise transmission

Observe regulations for structural noise protection, for
example DIN 4109.
Install the pump in a manner which reduces structure-borne
and airborne noise transmission. Vibration-absorbing
materials are suitable bases. Examples:
– Anti-vibration buffers
– Cork lining
– Sufficiently hard foam
5.1.6

Reserve space

Provide enough reserve space so that the pump can be
removed in the direction of the motor fan.
5.1.7

Fasteners

Fasten pump using screws.
5.2

Installation (Qualified specialist)

5.2.1

Installation tip concrete pool

Concrete pool with foil
Fig. 3
03|2020
Installation
EN 19