Real time waveform control operation mode with initial
current (intermittent up-down):
⑦ Push the torch trigger: arc is ignited and current
reaches the initial value.
⑧ Release it: current gradually rises.
⑨ Push it again: current stops rising.
⑩ Release it: current drops gradually.
to ②.
⑪ Push it again: current stops dropping, and then turn
⑫ If the torch trigger is not pushed after the current
begins to drop, the current will drop gradually till
arc stops.
Real time waveform control operation mode without
initial current (intermittent up-down):
⑦ Push the torch trigger: arc is ignited and current
rises gradually.
⑧ Release it: current stops rising.
⑨ Push it again: current drops gradually.
⑩ Release it: current stops dropping.
to ②.
⑪ Push it again: current rises gradually, and then turn
⑫ If the torch trigger is not pushed after the current
begins to drop, the current will drop gradually till
arc stops.
Manual pulsed single operation mode:
⑤ Push the torch trigger: arc is ignited and current
reaches the preset value.
⑥ Release it: current drops to pilot arc current value.
then turn to ②.
⑦ Push it again: current rises to the preset value, and
⑧ If push the torch trigger and release it at once, or
release the torch trigger and push it at once, arc will
stop.
Note: Preset value is the peak value; pilot arc value is
the base value. It is programmable.
Manual pulsed double operation mode:
⑤ Push the torch trigger: arc is ignited and current
reaches the preset value. The torch trigger can be
released at any time.
⑥ Push the torch trigger and release it at once: current
drops to pilot arc current value.
rises to the preset value, and then turn to ②.
⑦ Push the torch trigger and release it at once: current
⑧ If push the torch trigger twice within 0.5s, the
current will drop gradually, and arc will stop.
Note: Preset value is the peak value; pilot arc value is
the base value. It is programmable.
Pulsed welding with fixed frequency (5Hz) and fixed
duty cycle (50%):
⑥ Push the torch trigger: arc is ignited and current
reaches the initial value.
⑦ Release it: current gradually rises.
⑧ Push it again: current drops to pilot arc current
value, and the timing function is started.
⑨ If time is out, do peak-base switch.
⑩ Release the torch trigger: arc stops.
Note: Preset value is the peak value; pilot arc value is
the base value. It is programmable.