Code
Operation stipulation
Immediate executive code:
0X
Execute order X immediately.
Executive code in torch trigger
operation condition:
1X
Wait for the torch trigger operation, and
execute order X when pushing the torch
trigger.
Executive code in torch trigger
operation condition:
2X
Wait for the torch trigger operation, and
execute order X when releasing the
torch trigger.
Executive code in torch trigger
operation condition:
3X
Wait for the torch trigger operation. If
single operation, execute order X.
Otherwise, stop arc.
Executive code in torch trigger
operation condition:
Wait for the torch trigger operation. If
4X
single operation, no influence; if double
operation, execute order X; if triple or
quartic operation, stop arc.
The definition of order X:
X=0: Turn to next step
X=1: Go to the initial current and turn to next step
X=2: Go to the preset current and turn to next step
X=3: Go to the pilot arc current and turn to next step
X=4: Upslope and turn to next step
X=5: Stop upslope and turn to next step
X=6: Downslope to the pilot arc and turn to next step
X=7: Downslope till arc stops and turn to next step
X=8: Stop downslope and turn to next step
X=9: Stop arc
Smart Tig 310 P ACDC
2
1
2
1
4
5
7
8
2
1
2
1
5
7
8
4
3
3
9
0
3
2
2
0
2
4
2
4
0
3
0
2
2
1
7
0
4
3
6
9
2
1
7
0
4
3
6
9
9
0
0
0
2
0
0
0
9
0
0
0
2
0
0
0
0
0
0
0
0
0
0
0
9
0
0
0
2
0
0
0
0
7
0
0
2
3
9
0
0
7
0
0
2
3
9
0
Code
Transfer code in torch trigger operation
condition:
Wait for the torch trigger operation. Stop arc if
triple or quartic operation, turn to next step if
5X
single operation, and if double operation:
X=0: Turn to next step
X≠0: Turn to Step X (X=0~9)
Timing executive code:
Wait for the operation time, and during this
period, no influence if single or double
6X
operation, stop arc if triple or quartic
operation. If no operation of the torch trigger
and time is up, execute order X.
Timing transfer code:
Wait for the operation time, and during this
period, turn to next step if single or double
operation, stop arc if triple or quartic
7X
operation. If no operation of the torch trigger:
X=0: Turn to next step
X≠0: Turn to Step X (X=0~9)
Transfer code with torch trigger state:
X=0: Turn to next step immediately
8X
X≠0: Turn to Step X if the torch trigger is
pushed. Otherwise, turn to next step. (X=0~9)
Immediate transfer code:
9X
X=0: Turn to next step
X≠0: Turn to Step X (X=0~9)
Real time waveform control operation mode
with initial current (intermittent up-down)
Real time waveform control operation mode
without initial current (intermittent up-
down)
Manual pulsed single operation mode
Manual pulsed double operation mode
Pulsed welding with fixed frequency (5Hz)
and fixed duty cycle (50%)
Pulsed welding with unfixed frequency (the
cycle is 1/5 of the upslope time) and fixed
duty cycle (50%)
Operation stipulation
Pág. 62