GiBiDi SR2 Instrucciones Para La Instalación página 11

Ocultar thumbs Ver también para SR2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SR2
PROGRAMMING OF THE REMOTE CONTROL
During the programming procedure, 1 or 2 remote-control codes can be memorised. A single code produces a
cyclical movement (Up/Down); using two codes, the upward and downward motion can be controlled separately.
The remote-control transmission codes are programmed as follows:
1. Push the SEL key for 1 second. The LED D2 will start to blink;
2. Send the first code with the remote control chosen. The LED D2 shall start to blink rapidly;
3. Send the second code with the remote control chosen. The LED D2 stays on, signalling that
programming has been completed.
Note: If the second code is not sent within 8 seconds, the control unit leaves the programming phase, selecting
the operating mode only with one remote-control code.
This procedure can be repeated until a maximum of 25 remote control commands are memorised. If all 25 codes
have been memorised by repeating the programming, then LED D2 signals shall begin blinking, signalling that no
further memorisation operations are possible.
Remote-control commands can also be memorised without using the SEL key on the control unit. The procedure is
as follows:
1. Take a remote-control command already memorised and send the code to the control unit, keeping the
button pressed down for more than 20 seconds.
2. The control unit begins programming, triggering the blinking light and making some movements of the
shutter; new codes may be programmed during this phase by proceeding exactly as described above
starting from the second point.
Nota: if no code has been memorised yet, then the remote programming phase may be activated by any remote
control command.
FLASHING LIGHT OR COURTESY LIGHT
The control unit has a 230Vac 40W max. outlet for connection of a "FLASHING LIGHT" or "COURTESY LIGHT".
The control unit is supplied by the manufacturer with the Flashing Light function enabled (DIP-3-1 ON).
Under the blinking mode, the 230 Vac outlet is activated every time the automation is in movement, for the duration of
the motor time.
To enable the courtesy light, switch DIP-3-1 OFF. When the courtesy light is activated, the control unit enables the
230V outlet for 180 second every time an opening/closing command is issued.
PAUSE TIME: (PROGRAMMING THE AUTOMATIC CLOSING TIME, MAX. 90 SECONDS)
The control unit is supplied by the manufacturer without automatic closing.
To enable the automatic closing function, switch DIP-3-2 and DIP-3-3 following the logic shown in the table 1.
If don't want the automatic closing, switch DIP-3-2 and DIP-3-3 OFF.
11
UK

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

As07000

Tabla de contenido