G. Carefully rotate the rear housing180 degrees and reattach the two grounding straps to the
two studs near the grip bushings, using the two nuts removed in the previous step. Tighten
the two nuts. Figure 2-17 shows the straps reconnected.
H. Remove the blank from the location circled in Figure 2-17. Install the gland and power cord
in that location, and tighten the nut on the gland.
I.
At the original power cord location, install the blank or gland removed from the new
location.
J. Install the ferrite on the power cable, taking one turn as shown in Figure 2-16.
Ground wire connected
to ground stud
Cable gland
Figure 2-16: Reversed Location of Power Cord
K. Adhere the cable tie attachment to the enclosure at the location shown in Figure 2-16 and
Figure 2-17. Cable-tie the ferrite in place, and cut off any excess length from the tie.
L. Connect the ground wire to the ground stud, reconnect the power cord wires to the
connector and insert it in its socket on the main board.
Figure 2-15: Front Panel Removed
Cable tie and ferrite
Cable tie attachment
30205319
|