Function - Speck BADU OmniTronic Traducción De Las Instrucciones Para El Manejo Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 228
Description
Time-controlled
Exact time specifications are required for the time-controlled
programme. A starting time must be specified for the
backwash/rinse cycles and for the daily filter times. In time mode,
five filter cycles can be set per day. Set the various times and
press the "OK" key ( ) when the enter symbol is displayed. Then
a new cycle will be opened. The device takes daylight saving time
changes into account automatically.
I: Display of the current operating mode:
I: Interval-controlled
T: Time-controlled
Display of the optimal level switch status:
Display of the battery status:
3.3

Function

The BADU OmniTronic is a fully automatic backwash unit. The
electronics (circuit board) automatically take over the control of
the programme sequence i.e. the transition to all six positions:
Backwash (BW)
Rinse (RIN)
Filter (FIL)
Drain (DR)
Circulate (CIR)
Closed
Deactivation of the filter pump
The filter pump only runs depending on the BADU OmniTronic i.e.
the filter pump has to be controlled by the BADU OmniTronic. The
BADU OmniTronic requires its own power supply. Thus, due to
the internal power supply, backwash and rinse procedures can be
carried out automatically and independently, regardless of
external switching procedures for the filter programme. This is
18 EN
Water level in pool ok
Water level too low
Battery voltage present
Battery voltage too low, replace (CR2032)
05|2018

Publicidad

Tabla de contenido
loading

Tabla de contenido