Replacing The Fuses; Terminal Connection Table - Speck BADU OmniTronic Traducción De Las Instrucciones Para El Manejo Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 228
Contact load
Z1, Z2
11, 12, 14
Connection load
Lp, Np
Rocker switch
The rocker switch installed on the front turns the whole device on
and off.
The light on the rocker switch displays the operational readiness.
If the device is turned off, no contact information can be output via
Z1-Z2.
5.3.1

Replacing the fuses

There are two different fuses present.
4 A fuse for pumps with asynchronous motors
315 mA to safeguard the control unit's circuit board
5.3.2

Terminal connection table

Level sensor:
G, S1
VS pump and
Eco Touch-Pro pump
according to the colour
of the cables
230 V Input:
AC1, N = RS
AC2, N = FI
potential-free
input:
DC1, G = RS
DC2, F = FI
Fig. 4
05|2018
maximum 2 A, 250 V~ AC3
maximum 2 A, 250 V~ AC3
maximum 4 A, 250 V~ AC3
+/-
G
S1
h
GND
rd
br
gr
uh
AC3
AC2
AC1
N
GND
DC3
GND
DC2
GND
DC1
GND
DC5
GND
DC4
Installation
Contact:
Level magnetic valve
11, 14
Contact:
Release Z1, Z2
230 V output to 1~ pump
max. 1.1 kW:
Lp, Np
230 V Supply:
L, N
WG27.50.124-2-P
EN 27