Adjusting To High Elevation; Priming The Pump - L.B.White Foreman CI230 Manual Del Usuario E Instrucciones

Calefactor con encendido a fuel oil indirecto canalizable
Ocultar thumbs Ver también para Foreman CI230:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12
Foreman Ductable Oil Indirect-Fired Heater
Adjusting to High
Elevation
This heater burner air setting is factory set to operate
normally at 0-2,000 ft. above sea level. Allowance
for elevation must be taken into consideration when
operating above 2000 ft. A 1.84% rate reduction for
every 1000 feet above sea level is necessary for the
heater to operate safely. For service of re-rating the
heater, contact:
Beckett Technical Service
1-800-645-2876 or
Email: techservice@beckettcorp.com
NOTE: The fi ring rate (amount of Btu input) of the
burner must be maintained to meet the heat-
ing load that the appliance has been sized
to meet.
Thermostat
The optional remote thermostat is a fully enclosed NEMA
4X with a single stage temperature adjustment (±3°F/-
16°C degrees). L.B. White part #500-30125.
If a thermostat is not needed or required, select manual
setting on the thermostat switch.
Owner's Manual • Foreman
If a thermostat is required, lift the thermostat outlet cover
and plug the male prong of the thermostat cord to the
thermostat outlet of the heater. Select the thermostat
setting on the thermostat toggle switch.
Thermostat Outlet
WARNING
• ALWAYS cover the thermostat outlet when not in use.
• DO NOT plug an appliance to the thermostat outlet.

Priming the Pump

Pump priming is not required nor necessary with the
Foreman Oil heater.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Foreman ci500Foreman ci750

Tabla de contenido