Lenze L-force 9400 Serie Instrucciones Para El Montaje página 45

Base de montaje
Ocultar thumbs Ver también para L-force 9400 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

0
3
Fig.7-5
Stripping lengths of the motor cable
Type
Device size I
Device size II
Device size III
How to proceed:
1. Strip the motor cable  according to dimensions given.
2. Fold back the shield of the motor cable  over the cable sheath.
3. Stabilise the shield with self-adhesive conductive foil 
(recommendation).
4. Fix the shield and conductive foil with heat-shrinkable tube  on the
cable sheath.
5. Fasten cable lugs or wire end ferrules.
6. Connect the shields separately to the shield sheet using shield clamps (no
strain relief).
EDK94ZPM113 DE/EN/FR/ES/IT 1.0
1
2
c
a
80
90
100
Electrical installation
Terminal assignment
a
d
Dimensions [mm]
b
c
8
25
8
30
10
30
4
Wiring
b
U
V
M5
W
PE
BD1/T1
BD2/T2
e
SSP94MOTL1
d
e
150
8
160
8
170
8
45

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

L-force e94azpm serie

Tabla de contenido