WARNING
Fire hazard! Never use the product for:
- extracting and/or filtering flammable, glowing or
burning particles or solids or liquids
- extracting and/or filtering of aggressive fumes (such
as hydrochloric acid) or sharp particles
- extracting of aggressive fumes (such as hydrochloric
acid) or sharp particles
- extracting and/or filtering dust particles which are
released when welding surfaces treated with primer
- sucking cigarettes, cigars, oiled tissues, and other
burning particles, objects, and acids
WARNING
Never use the product for:
- oil mist
- paint mist
- extraction of hot gases (more than 45°C/113°F
continuously)
- explosive environments or explosive substances/
gases
Note: this list is not all-embracing.

Installation

- The installation of this product is exclusively reserved to well
authorised, trained and qualified engineers.
- Electric connection to be executed in accordance with local
requirements. Ensure compliance with the EMC regulatory
arrangements.
- During installation, always use Personal Protective Equipment
(PPE) to avoid injury. This also applies for persons who enter
the work area during installation.
- Use sufficient climbing gear and safety guards when working
on a higher level than 2 meter (6.5 ft) (local restrictions may
apply).
- Never install the product in front of entrances and exits which
must be used for emerency services.
- Mind any gas and water pipes and electric cables.
- Make sure the wall, ceiling or support system are strong
enough to carry the product.
- Ensure the workspace is well illuminated.
- Use common sense. Stay alert and keep your attention to your
work. Do not install the product when you are under the
influence of drugs, alcohol or medicine.
- Make sure that the workshop, in the vicinity of the product,
contains sufficient approved fire extinguishers.
- Air containing particles such as chromium, nickel, beryllium,
cadmium, lead etc., which is a health hazard, should never be
recycled. This air must always be brought outside the working
area.
Use
- Inspect the product and check it for damage. Verify the
functioning of the safety features.
- During use, always use Personal Protective Equipment (PPE)
to avoid injury. This also applies for persons who enter the
work area.
- Check the working environment. Do not allow unauthorised
persons to enter the working environment.
- Protect the product against water and humidity.
- Make sure the room is always sufficiently ventilated; this
applies especially to confined spaces.
Service, maintenance and repairs
- Observe the maintenance intervals given in this manual.
Overdue maintenance can lead to high costs for repair and
revisions and can render the guarantee null and void.
- During service, maintenance and repair jobs, always use
Personal Protective Equipment (PPE) to avoid injury. This also
applies for persons who enter the work area.
- Always use tools, materials, lubricants and service techniques
which have been approved by the manufacturer. Never use
worn tools and do not leave any tools in or on the product.
- Safety features which have been removed for service,
maintenance or repairs, must be put back immediately after
0507340050/010111/D EDS
finishing these jobs and it must be checked that they still
function properly.
- Use sufficient climbing gear and safety guards when working
on a higher level than 2 meter (6.5 ft) (local restrictions may
apply).
ATTENTION
Service, maintenance and repairs should only be
performed in accordance with directive TRGS 560 by
authorised, qualified and trained persons (skilled)
using appropriate work practices.
WARNING
Before carrying out service, maintenance and/or
repair jobs:
- fully disconnect the machine from the mains
- disconnect compressed air supply
WARNING
Always wear face mask and gloves during filter
exchange/cleaning.
Industrial vacuum cleaner used during service and
maintenance should meet dust class H according to EN
60335-2-69.
4
INSTALLATION
4.1
Positioning
The EDS can be mounted on the floor or on a platform. Make
sure the outlet nozzles can be directed to the welding fume layer
without obstruction.
Depending on the circumstances, it might be necessary to use
a longer or shorter duct than the 1,5 m (5 ft) one which is
standard supplied.
Make sure there is sufficient space (min. 750 mm/2.5
ft) above the filter unit in view of filter exchange.
Refer to Fig. II on page 75 for positioning examples.
4.2

Tools and requirements

The following tools and requirements are needed to install the
system:
- lifting equipment (e.g. fork-lift truck, crane)
- climbing gear (e.g. scissor lift)
- cordless drill
- step drill
- wrench (metric sizes 10-13-17)
- screw driver
- level
2
- mains cable 4 mm
(AWG 12); 3 cores + mass
- mains plug
- self-tapping screws
- duct tape
4.3
Unpacking
Check that the product is complete. The package should
contain:
Filter unit
- filter base
- control box on mounting plate
- filter base frame (two-piece)
- drum + drum flange
- drum lid
- bush
[inside drum]
- adapter Ø 400 mm
[inside drum]
- duct connector Ø 400 mm with KEN-LOK sealing
- mounting material for base frame
[inside drum]
[inside drum]