Symptom
Problem
EDS does not start in
System not working.
mode.
AUTO
Low airflow or noisy
System not working
fan.
properly.
System keeps falling
Insufficient airflow.
back to 30Hz.
System vibrates at
Noise nuisance.
certain frequencies.
8
SPARE PARTS
The following spare parts are available for the product (refer to
exploded view Fig. V on page 77).
Art. no.
Description
0042000040
Membrane valve
0046020040
Pressure regulating valve + pressure gauge
0046030010
Pressure relief valve 6-10 bar
0202951050
Lid housing
0719020040
Filter cover plate
0719020060
Filter ring
0720206050
Drum flange
9850070050
Drum 100 incl. lid, wheels and handles
0810100050
Sealing membrane valve
9820040100
PLC EDS; incl. varistor + software
9824000080
Closing valve for DRUM 100
9824000090
Piston mechanism
9824000200
Revision set bottom cleaning mechanism
9850060080
Filter FCC 150 (two-piece)
9870050010
Modification kit cleaning mechanism (top)
Control panel
Refer to last page of supplied electrical diagram (=control panel "as-
built").
9
ELECTRICAL DIAGRAM
Refer to the separately supplied electrical diagram.
10
DISPOSAL
After life of the product, dispose it of in accordance with federal,
state or local regulations.
0507340050/010111/D EDS
Possible cause
System without battery pack: system
has been powered down (no mains up to
80 hours).
Timer or current date not programmed or
erased due to missing battery pack (no
mains over 80 hours).
Fan rotation might be wrong.
Potentiometer dirty or broken.
Depending on the length of the duct the
unit might have the same frequency as
the imposed fan frequency.
CE DECLARATION
CE declaration of conformity for machinery
We, Plymovent, Wezelkoog 11, 1822 BL Alkmaar, the
Netherlands, herewith declare, on our own responsibility, that
the product(s):
- EDS
which this declaration refers to, is/are in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- EMC 2004/108 EC
- LVD 2006/95 EC
and is/are in conformity with the following harmonized
standard(s) and/or other such normative documents +
amendments, if any:
- EN ISO 12100-1:2003 (safety of machinery)
- EN ISO 12100-2:2003 (safety of machinery)
- EN ISO 13857:2008 (safety distances)
- EN 55011
- EN-IEC 60335-1
- EN-IEC 60335-2
- EN-IEC 60335-2-65
- EN-IEC 61000-3-3
- EN-IEC 61000-6-2
Alkmaar, 1st January 2011
C.J.M. Knijn
Chief Operations Officer
Solution
Turn off main switch (ref. Fig. 5.1F). Turn
rotary knob
- 0 -
SYSTEM MAN
(ref. Fig. 5.1E). Turn on main switch and
wait approx. 10 seconds. Turn rotary
knob to
mode.
AUTO
Reprogram current date and time.
Restart system.
Order a battery pack at your distributor
and program current date and time to
avoid future problems. With battery pack
the system will have a two year power
back-up.
Follow the arrow on the fan housing and
check if impeller direction matches the
indicator. If not, change motor direction
by inverting motor phases between
frequency inverter and motor.
Clean potentiometer with compressed air
or replace.
Sweep the system with option 4-64 of
the frequency inverter and follow
instructions as displayed.
to 0
AUTO
EN - 25