The display shows:
>On
Off
S/W Time:
Off
Move the '>' cursor to 'On': Press
Confirm 'On': Press OK.
The display shows:
EU
Press
to select the applicable time zone. Press OK.
The display shows (assuming you have set European time):
>On
Off
S/W Time:
On
EU
The weekly timer of the PLC arranges the on/off days and times
of the system.
Default setting:
- Monday to Friday
- On: 07:00 h
- Off: 18:00 h
The weekly timer has three screens for programming purposes.
In this way additional on/off days and/or times can be
programmed.
Change or program additional weekly timer settings in
consultation with the user/customer.
To change or add timer settings, proceed as follows.
Press
to show time + date.
Press ESC.
Select 'Set Param': Press
Press OK.
Timer, screen 1
B1
1
Weekdays (daily)
D=MTWTF--
On-time (07:00 h)
On =07:00
Off-time (18:00 h)
Off =18:00
Press
or
to change cursor position. Press
change value.
M = Monday; T = Tuesday; W = Wednesday; T = Thursday;
F = Friday; S = Saturday; S = Sunday
Press OK.
If desired, screens 2 and 3 can be used to set additional on/off
days/times of the system.

4.5.3 Frequency inverter

The frequency inverter should automatically run in
Check LED on frequency inverter indicating that it runs in
mode.
AUTO
If not: push button "Auto On".
0507340050/010111/D EDS
or
.
or
.
or
to
mode.
AUTO
5

USE

WARNING
During use, always use Personal Protective Equipment
(PPE) to avoid injury. This also applies for persons who
enter the work area.
5.1
Control panel
The control panel contains the following controls and indicators:
Fig. 5.1
A
control light
FREQUENCY INVERTER RUNNING
System = OK; frequency inverter running.
B
control light
FAILURE INSTALLATION
System failure; check display of PLC and frequency inverter
for further action.
C
potentiometer
FANSPEED
To regulate fan speed.
D buzzer
In case of a system failure indicated by the control light (B),
the buzzer emits an acoustic signal simultaneously.
E
rotary knob
SYSTEM MAN
F
main switch
Fig. 5.1: Control panel
5.2
Control
The system is supposed to run in automatic mode. In this time
controlled operation, the system will start and stop
automatically at the preset days and times. Manual mode is only
used for incidental use, e.g. outside regular working hours.
During use, make sure the handle of the drum is in vertical
position (=open).

5.2.1 Time controlled operation

Turn on the main switch (ref. Fig. 5.1F).
Wait approx. 10 seconds for the system to initialize.
Turn the rotary knob (ref. Fig. 5.1E) to
In
mode the system runs fully automatically, according to
AUTO
the preset timer settings. To modify or add timer settings, refer
to paragraph 4.5.2.
ATTENTION
Do not turn off the main switch.
Make sure power supply and compressed air are
available after working hours at all times.
(green)
(red)
0-100%
- 0 -
(manual - off - automatic)
AUTO
A
B
C
D
E
F
(automatic).
AUTO
EN - 22