DESCRIPTION OF THE SYSTEM
The standard system consists of the following components:
−
The electromechanical actuator positioned over the door allows the moving of the sliding wings. During
normal operating mode, the safety guard must be closed.
−
The crossing detectors, an inner one and an outer one, detect the approaching of things and persons and
send the opening signal to the electromechanical actuator.
−
The closing photocell, installed inside the crossing light, prevents the wings from striking things or persons
during the closing phase.
−
The functions selector allows the selecting of the type of desired operating mode.
R6/RK6
DOOR OPENED
UNIDIRECTIONAL
OPENING
BI-DIRECTIONAL
OPENING
PARTIAL
OPENING
DOOR CLOSED
STOP
The "STOP" position does not allow the tripping of the batteries in an emergency situation.
DOOR STOPPED SITUATION
Carry out following checks in case of stops or system malfunctions:
− Check that the automatic system is powered by the 230 V~ mains voltage.
− Check the type of operating mode set via the selector.
− Check that the movement of the wings is not jammed by foreign objects.
− Check that the photocells are clean and that no objects are placed in between.
− Check that there are no continuous motion elements near the door which could affect the crossing detector.
If the system does not resume operation after all the aforementioned checks, call the Service Center.
RELEASE OPERATION
In case of an emergency, in order to open the jammed door, lower release lever S and manually move the
wings to opening position.