Guide for framed door supplied by us (Fig. 7): reduce M as much as necessary.
Guide for crystal door supplied by us (Fig. 8): wings N shall not press on crystal.
2.7. GTE tie rod positions (Fig.9)
GTE 2+2 DOOR WING ON LEFT SIDE, GTE 1+1 OPENING DOOR ON LEFT SIDE: Fig.9a.
GTE 2+2 DOOR WINGS ON RIGHT SIDE, GTE 1+1 OPENING DOOR ON RIGHT SIDE: Fig.9b.
Once the assembly and the adjustment of the door wings on the wheel units have been carried out, BRING
DOOR WINGS IN CLOSING POSITION.
Loosening Q and pulling P, the door wing J moves towards P.
Loosening P and pulling Q, the door wing J moves towards Q.
During these operations the external door wing K must be in closing position. By screwing both Q and P, cable
tension increases. For 2+2 automation door wings follow the same instructions, first on one side and then on the
other, always with DOOR WINGS IN CLOSING POSITION.
2.8. Door wing-carriage position (Fig.10 a/b/c)
The closing quotes shall be respected for all the operators making the locking device stucking possible.
3. ELECTRICAL CONNECTION
The components inside the automatic system are connected as shown in fig. 11. Refer to the diagrams of fig. 15
concerning the control and safety connections:
3.1. Controls
CONTACT
FUNCTION
1
2
Automatic closing
1
3A
Total opening side A
1
3B
Total opening side B
27
3A
Partial opening side A
27
3B
Partial opening side B
1
4
Closing
1
8
Safety
1
9
STOP
1
28
Locking exclusion
1
29
Reset
SAFETY
Safety
CARD
3.2. Dip-switches
FUNCTION
1
Locking function
NOTE
The selectors R6/RK6 and COM96 automatically select the automatic
closing.
It is used when the automatic closing is not set.
If the contact is turned on during the closing run, it causes the re-
opening. It is not set when the door is closed. The contact can be
excluded only for verification and checking of the automation by
using a 1 to 8 bridge.
When the contact 1 -9 is open, every normal and
function is excluded.
The closed contact puts off duty the door wing locker; with R6/RK6
exclusion takes place automatically in position
position
and
.
By pressing it, it cancels all acquired data. After 3 seconds, the
automation can proceed with a new acquisition.
In order to insert the safety card (CELAS photocell card type), remove
jumper JP. The function is the same as control 1-8. Contact 1-8 and
safety card contact are in line.
NOTE
ON
Control turns off the power supply of the locker during the opening/
closing operation. (Locker normally powered).
18
.
emergency
, with COM96 in