6.7.2
Connecting to a Wifi Network
In order to use certain features like online software
update and WLAN printing, an active WLAN connection
has to be established.
Procedure:
1. End the test.
2. In the start screen, select "Options >> Settings >>
WLAN".
3. Select the WLAN network to connect.
4. Enter the WLAN password and save with <Connect>.
5. Exit the menu with <Back>.
Setting up the WLAN connection is completed.
6.7.3
Updating software
i
The test values are installed standard on the
EPS 118 for Bosch and non-Bosch injectors. Update
the software at regular intervals "EPS 118". This will
ensure that the test values are always current.
i
When updating the software via a USB stick, the file
"eps118.zip" must be downloaded, saved on a PC
and opened (decompressed). The files contained
must then be copied to the uppermost directory
of a USB stick. The file "eps118.zip" is available on
the Internet site
http://epsdata.bosch-automotive.com/eps/
. EPS 118 has the link to the current
EPS118/eps118.zip
software integrated in the system. When updating
the software over the Internet (Option >> Update
software (Internet)), EPS 118 accesses this Internet
site.
!
Before updating the software, ensure that EPS 118
has been switched on.
Procedure:
1. End the test.
2. If the EPS 118 has Internet access, select "Options
>> Update software (Internet)" on the Start screen.
Otherwise, insert the USB stick with the software
into a USB port and select "Options >> Update soft-
ware (USB)" on the Start screen.
3. Follow the on screen instructions in order to com-
plete the process.
This completes software update.
Robert Bosch GmbH
Commissioning | EPS 118 | 67
6.7.4
Entering the owners information
It is recommendable to enter the owner's personal in-
formation. This information will be used in the generat-
ed reports and logs.
Procedure:
1. End the test.
2. In the start screen, select "Options >> Settings >>
User information".
3. Fill in all input boxes.
4. Save the settings, and exit with <Back>.
The entry of owner information is now finished.
6.7.5
Backing up user data and protocols
i
Back up user data and protocols after the initial
commissioning and at regular intervals.
Procedure:
1. End the test.
2. Connect USB stick to USB port.
3. On the Start screen, select "Options >> Settings >>
Backup/Restore".
4. Select "Backup".
5. Follow the instructions on the screen to complete
the process.
The backup of the user data and protocols is now
complete.
i
By selecting "Restore" under "Options >> Settings
>> Backup/Restore" the user data and protocols on
the EPS 118 can be restored.
6.7.6
Bleeding the system
Procedure:
¶
Bleed the system (see sec. 8.2.8).
i
After the ventilation, the test oil level on the oil level
indicator (fig.°1, item 4) must be checked. If the test
oil level is below the mark on the oil level indicator
(fig.°1, item 4), test oil must be refilled
(see Section 6.4) until the test oil level is back above
the mark on the oil level indicator (fig.°1, item 4).
"
Initial commissioning completed.