Contact Input/Output Connections For Pendant Type - Ikegami IPD-Q38 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6-2. Contact input/output connections for Pendant type

Be sure the power is not applied before doing this process.
Connect the Non-voltage contact (dry contact) output or open-collector output of an external
device to the IN1 terminal.
The system is standard equipped with the AUD, MIC and IN1 functions. Three of the AUD, MIC,
IN1, IN2, OUT1 and OUT2 functions may also be optionally selected. You will be charged for
customization.
The standard configuration of a Pendant type only provides IN1. (There is no OUT1)
(A pull-up resistor is required at OUT 1/OUT 2 as it is an open collector output of maximum load
of 24V, 50mA )
■ Connection example drawing:
AC24
- It works as set on the I/O setting screen.
Please refer to the chapter of the In/Out setup in the application manual for further details.
AC24
AUD
GND
MIC
GND
E-8
IN1
GND
Non-voltage contact

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido