GiBiDi SC24 Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
12
UK
FUNCTION PROGRAMMING (DIP SWITCH-SW1)
The settings are stored during the rest phase (gate closed).
DIP
Status
DIP 1
OFF
DIP 2
OFF
DIP 1
ON
DIP 2
OFF
DIP 1
OFF
DIP 2
ON
DIP 1
ON
DIP 2
ON
DIP 3
ON
DIP3
OFF
DIP 4
ON
DIP 4
OFF
DIP 5
ON
DIP 5
OFF
DIP 6
ON
DIP 6
OFF
DIP 7
ON
DIP 7
OFF
DIP 8
ON
DIP 8
OFF
DIP 9
ON
DIP 9
OFF
DIP 10
ON
DIP 10
OFF
Functuion
STEP-BY-STEP WITH STOP
STEP-BY-STEP
CONDOMINIUM
DEAD MAN
PRE-FLASHING
SAFETY DEVICE TEST
PHOTOCELL DURING OPENING
AUTOMATIC CLOSING
DECELERATION
FAST CLOSING
LED POWER SUPPLY
Description
I Start pulse : OPEN
II Start pulse : STOP (will not reclose automatically)
III Start pulse :
CLOSE
IV Start pulse :
OPEN
I Start pulse :
OPEN
II Start pulse :
CLOSE
III Start pulse :
OPEN
During opening does not receive other Start commands after the first one; during Pause
subsequent Start commands reload the pause time
I Start pulse :
OPEN
Subsequent Start pulses : Uninfluential
Pause from opening limit switch
Start pulse during pause : Reloads the pause time (if dip 6 ON)
Subsequent Start pulse :
OPEN
If Start button is held down : OPEN
If Pedestrian button is held down :
Enables pre-flashing of 2 seconds before motor activation during opening an d closing
Disables pre-flashing
Enables the safety device TEST before activating the opening and closing cycle.
The test consists of temporarily cutting the power to the devices (terminal 18 +SAFETY)
and checking proper switching of the contact (terminal 13 SAFETY).
The cycle can only start if the devices work perfectly, if not, three prolonged flashes
indicate the fault.
Disables the safety device test.
When the photocell is intercepted during both opening and closing, the gate motion is
locked until the photocell is freed. Subsequently, there is always an opening phase.
Disables the photocell function during opening.
Enables automatic closing after the pause time adjustable with the trimmer TR5 PAUSE
between 2 and 215 seconds.
Disables automatic closing.
Enables deceleration during both opening and closing when the respective limit switch is
intercepted. The deceleration speed is adjusted with the trimmer TR3 SLOW. This function
provides for use of 4 magnets (see drawing 2)
Disables the deceleration function. Only 2 magnets are required (see drawing 2)
Reduces the pause time to 3 seconds after interven tion of one of the photocells.
Disables the fast closing function.
Not used
Not used
Supplies the LEDs (which will come on dependin g on the respective contact).
After proper installation, the LED power supply can be deactiv ated to save energy.
Disables the warning LED power supply.
or CLOSES (if dip 6 OFF)
CLOSE
SC24