Installation Warnings; Warnings For The User - GiBiDi SC24 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
10
UK

INSTALLATION WARNINGS

•Before proceeding with installation, fit a magnetothermal or differential switch with a maximum capacity of
10A upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening
distance of at least 3 mm.
•To prevent possible interference, differentiate the power cables and always keep them separate (minimum
cross-section 1.5 mm²) from the signal cables (minimum cross-section 0.5 mm²).
•Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that are connected to the same N.C. (normally closed) input, and in parallel all
the devices that share the same N.O. (normally open) input. Incorrect installation or improper use of the product
may compromise system safety.
•Keep all the materials contained in the packaging away from children, since they pose a potential risk.
•The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific application are not used.
•After installation, always carefully check proper functioning of the system and the devices used.
•This instruction manual addresses persons qualified for installation of "live equipment". Therefore, good
technical knowledge and professional practice in compliance with the regulations in force are required.
•Maintenance must be carried out by qualified personnel.
•Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
•This control unit may only be used for the purpose for which it was designed, i.e. monitoring of a 24 VDC
sliding gate, maximum length 3m, maximum weight 350 kg.
•Use of the product for purposes different from the intended use has not been tested by the manufacturer,
therefore any work is carried out on full responsibility of the installer.
•Mark the automated device with visible warning plates.
•Warn the user that children or animals may not play or stand around near the gate.
•Appropriately protect the danger points (for example, using a sensitive frame).
THE ANTI-CRUSHING FUNCTION DOES NOT RELIEVE THE INSTALLER FROM THE OBLIGATION
TO INSTALL THE SAFETY DEVICES AS REQUIRED BY THE REGULATIONS IN FORCE.

WARNINGS FOR THE USER

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel
using original and certified materials.
SC24

Publicidad

Tabla de contenido
loading

Tabla de contenido