SC24
DEFAULT SETTINGS
DIP 1 and DIP 2 both OFF: Step-by-step with stop
DIP 3 OFF: Pre-flashing disabled
DIP 4 OFF: Safety device test disabled
DIP 5 OFF: Opening photocell disabled
DIP 6 ON: Automatic closing enabled
DIP 7 OFF: Deceleration disabled
DIP 8 OFF: Fast closing disabled
DIP 9 OFF: Uninfluential
DIP 10 ON: LEDs powered
Closing limit switch
motor stop
TRIMMER ADJUSTMENT
The trimmers TR1, TR2, TR3, TR4 can be adjusted also during gate movement and hence the effect
immediately be checked.
The trimmer TR5 is stored only during the rest phase (gate closed).
Trimmer
Function
TR1
FORCE
TR2
AMP .FORCE
TR3
SLOW
TR4
AMP . SLOW
TR5
PAUSE
DEFAULT SETTINGS
TRIMMER TR1 TR3 TR5 adjusted to minimum
TRIMMER TR2 TR4 adjusted to maximum
400 500mm
Limit switch slowing
down in closing
Description
Adjusts the motor FORCE level. The force is increased by turning the trimmer clockwise.
Adjusts the intervention threshold of the anti-crushing function during non-decelerated motion. When it intervenes the
motion is locked and inverted for 2 seconds in order to free the obstacle. The intervention threshold is increased by
turning the trimmer clockwise.
Adjusts the DECELERATION level. Deceleration is decreased by turning the trimmer clockwise (turning clockwise the
gate speed/force is increased)
Adjusts the intervention threshold of the anti-crushing function during slow motion. When it intervenes the motion is
locked and inverted for 2 seconds in order to free the obstacle. The intervention threshold is increased by turning the
trimmer clockwise.
Adjusts the PAUSE TIME from 2 to 215 seconds. The value is increased by turning the t rimmer clockwise.
Opening limit switch
motor stop
Limit switch slowing
down in opening
13