FAn only MoDe:
• Use this mode when you'd like to circulate air or
exhaust stale air but not run the air conditioner .
• Open the vent in fan mode, but for most efficiency
keep it closed during cooling mode .
• The display shows the ambient room temperature .
DRy MoDe:
• The unit functions as a dehumidifier in dry mode .
• Some cooling may occur during this mode .
eneRGy sAve FeATURe:
• With a press of the Energy Save button, the fan
continues to blow air through the compressor and
provide cooled air . The fan will run for 2 minutes
every 10 minutes, and cooling will resume once the
room temperature exceeds the set temperature .
sleep MoDe FeATURe:
• When you push the sleep button, the selected tem-
perature will increase (cooling) or decrease (heat-
ing) by 1°C/2°F after 30 minutes . The temperature
will then increase (cooling) or decrease (heating) by
another 1°C/2°F after an additional 30 minutes .
• The new temperature will be maintained for 7
hours before it returns to the originally selected
temperature . This ends Sleep mode and the unit
will continue to operate as originally programmed .
TIMeR & AUTo sTART/sTop FeATURe:
• The timer indicator lights are for two separate
functions, one to automatically turn the unit on and
another to automatically shut it off . Both programs
can be set at the same time .
setting the unit to automatically turn off:
• Push the timer button once (if dehumidifier is run-
ning) or twice (if dehumidifier is not running) until
the 'OFF' indicator illuminates
• Use the + and – pad to select the number of hours
before the unit automatically turns off .
• The time will be programmed after 5 seconds of
inactivity and the display will return to show the
humidity level .
setting the unit to automatically turn on:
• Push the timer button once (if dehumidifier is not
running) or twice (if dehumidifier is running) until
the 'ON' indicator illuminates .
• Use the + and – pad to select the number of hours
before the unit automatically turns off .
• The time will be programmed after 5 seconds of
inactivity and the display will return to show the
humidity level .
noTe: Both 'ON' and 'OFF' indicators can be illumi-
nated—the unit will automatically turn itself on and
off according to the programmed times .
peRsonAl MAppInG TeMpeRATURe sensoR:
• NOTE: This feature can be activated from the
remote control ONLY and on select models .
The remote control acts as a remote thermostat
allowing for the precise temperature control at its
location .
• To activate the personal mapping temperature
sensor, point the remote control towards the unit
and press the PMTS button . The remote display
is actual temperature at its location . The remote
control will send this signal to the air conditioner
every 3 minutes interval until press the PMTS
button again .
• If the unit does not receive the remote signal
during any 7 minutes interval, the unit will beep
to indicate the personal mapping temperature
sensor mode has ended .