If a supply hose longer than 5 metres should be required, you should replace the existing hose with another
one whose section must be chosen according to Table 3. To carry out this operation remove top cap (mark 50
on the general parts explosion), the terminals of the supply hose are on top of the middle panel (mark 56 on
the general parts explosion) See Fig.4.
EQUIPMENT
GALA MIG 6007
2.2 VOLTAGE CHANGE.
GALA MIG 6007 have two voltages (standard version at 230/400 V). Therefore it is necessary to check that
the voltage selected on the equipment coincides with the mains voltage.
BLACK
BROWN
BLUE
WHITE
400 V
Standard equipment leave the factory with the voltage selected at 400 V. To change to 230V voltage
remove the lid on the rear of the equipment, changing the location of the terminals as shown in the picture.
DO NOT FORGET TO FIT THE EARTH CONNECTION INTO THE PLUG.
MAKE SURE THE MAINS VOLTAGE COINCIDES WITH
GALA INDUSTRIAL.. Instructions Manual.
The connection to the mains is made from the intake hose. The Figure on the left
shows the connection of the intake hose to the two most common types of
standardised plug (IEC 309-2). In this figure L1, L2 and L3 show the phase cables
and PE represents the earth protection conductor.
DO NOT FORGET TO FIT THE EARTH CONNECTION INTO THE PLUG.
1
Table 3.
Electrical data of the installation.
CONNECTION AT 230 V
10 m
15 m
2
16 mm
16 mm
Fig.5
CARRY OUT THE
VOLTAGE CHANGE
OPERATION WITH THE
DISCONNECTED FROM
THAT ESTABLISHED IN THE MACHINE.
Fig.4
GROUND
GR
BL
BR
INTAKE HOSE (INSULATION)
CONNECTION AT 400 V
20 m
10 m
2
2
25 mm
10 mm
Voltage change system.
BLACK
MACHINE
BROWN
BLUE
MAINS
WHITE
15 m
20 m
2
2
2
10 mm
16 mm
230 V