3.2.1. REGULATION LEVELS.
The traditional current level can be determined in table 4 (as per standard EN 60974-1) for each
regulation point of the welding voltage of the equipment. The traditional level corresponds to the appropriate
current values for MG welding with pure CO
welding with gas mixture (75% CO
GALA INDUSTRIAL.. Instructions Manual.
. We have added the approximate current level values for MAG
2
+ 25% Ar).
2
Table 4.
Traditional regulation levels (CO
GALA MIG 6007
NO-
SCALE
Reg.
LOAD
U
(V)
2o
1
17,0
2
17,4
3
17,7
4
18,1
5
18,5
I
6
18,9
7
19,2
8
19,6
9
19,9
10
20,2
1
20,6
2
21,2
3
21,8
4
22,3
5
22,9
II
6
23,4
7
24,0
8
24,5
9
25,0
10
25,5
1
26,2
2
27,1
3
28,0
4
28,9
5
29,9
III
6
30,8
7
31,7
8
32,6
9
33,5
10
34,3
1
35,6
2
37,3
3
39,0
4
40,7
5
42,6
IV
6
44,5
7
46,3
8
48,2
9
50,1
10
52,0
) and gas mixture.
2
TRADITIONAL
GAS MIXTURE
(CO
)
2
U
(A)
I
(A)
U
(A)
2
2
2
16,1
40
71
16,4
48
77
16,7
53
82
17,0
59
88
17,2
64
93
17,5
69
98
17,7
75
103
18,0
79
108
18,2
84
113
18,4
89
117
18,7
95
123
19,1
103
131
19,6
111
140
20,0
119
148
20,4
127
156
20,7
135
164
21,1
143
171
21,5
150
179
21,9
157
186
22,2
164
193
22,7
174
203
23,4
187
216
24,0
200
229
24,7
213
242
25,3
227
255
26,0
240
268
26,7
253
282
27,3
266
294
27,9
278
307
28,5
290
319
29,4
308
336
30,6
333
361
31,9
357
386
33,1
382
410
34,4
409
437
35,8
435
464
37,1
462
490
38,4
490
517
39,8
520
544
41,1
550
570
25
I
(A)
2
15,5
15,9
16,2
16,4
16,7
17,1
17,2
17,5
17,9
17,9
18,2
18,5
18,9
19,4
19,7
20,1
20,6
20,9
21,3
21,6
22,1
22,5
22,9
24,1
24,5
24,8
26,1
26,4
26,8
28,0
28,8
29,2
29,6
32,5
32,9
33,3
36,5
36,9
37,3
40,6