gala gar MIG 6007 Manual Técnico De Instrucciones página 29

Equipos industriales de soldadura mig/mag de regulación electromecánica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SYMPTOM. ANOMALY.
THE WELDING START IS VERY
AGGRESSIVE.
THERE ARE MANY
PROJECTIONS.
SPECIALIZED PERSONNEL MUST CARRY OUT ANY WORK ON THE EQUIPMENT.
BOTH AT THE BEGINNING AND END OF A REPAIR CHECK THE EQUIPMENT INSULATION LEVELS.
DISCONNECT THE ELECTRONIC BOARDS WHEN MEASURING THE INSULATION.
The insulation-measuring device will have 500 V DC and will be applied to the following points of the
circuit:
-
Intake rectifier-Earth: Ra> 50 Mohms
-
Outlet rectifier-Earth: Ra> 50 Mohms
-
Switch l2 - Outlet rectifier: Ra> 50 Mohms
-
Control circuit-Earth: Ra> 50 Mohms
In the event that lack of insulation is observed it is likely that this is due to the accumulation of metal
dust on the inside of the equipment.
BOTH AT THE BEGINNING AND END OF A REPAIR, BLOW THE INSIDE OF THE EQUIPMENT WITH
GALA INDUSTRIAL.. Instructions Manual.
PROBABLE CAUSE.
Spotting jobs are being carried out with high
inductance intake.
Aluminium is being welded with a drawing
problem, which causes incorrect arc ignition as
the wire is slowed down on knocking against
the piece.
The motor acceleration ramp is very low,
reaching a high speed in the initial priming
process.
The wire length at onset of welding process is
too long.
COMPRESSED AIR.
POSSIBLE SOLUTION.
Place the earth tap at the lowest inductance value
Examine the drawing process. Prevent the gun from
making "knots", keeping it in a straight line. The
wire must not be slowed down when it knocks
against the piece
Suitably
regulate
the
potentiometer of the existing motor in the wire-feed
unit.
Suitably regulate the existing final wire length
potentiometer in the wire-feed unit to obtain the
LEAST final wire length at the end of the welding
process.
29
acceleration
ramp

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

434.00.000434.81.000

Tabla de contenido