Figure 6: HSM2955(R) terminal connections
Corbus
RED
BLK
YEL
GRN
AUX
AUX
Power
COM
Tamper
TAM HSM2955 Module Tamper Input
Speaker/Mic M1
M2
M3
M4
Speakers
SPK1
SPK2
Audio
AOUT
GND
AIN
Phone Line RNG
TIP
R-1
T-1
Ground
EGND Earth Ground for Telco circuit

3.3 Enrollment

The HSM2955(R) audio verification module can be automatically or manually enrolled at the panel
keypad. See below for enrollment options.
Automatic Enrollment - Enter section [902] and press [000] [*] to automatically enroll all new
modules.
Manual Enrollment - To manually enroll the HSM2955(R) enter section [902] then select [001] [*].
When prompted, enter the serial number found on the device. An error tone sounds if an invalid
serial number is entered. The serial number and slot assignment is displayed when the module has
been enrolled successfully.
Confirm Enrollment - To confirm enrollment, enter section [903] then select [108][*].
Delete - Enter [902][108][*] to remove the HSM2955(R) module from the system.
Labels - Enter [000][808][*] to customize the module label. See the Alarm Panel Installation Manual
for more details.

4. Operation

The HSM2955(R) module is intended to be used only with the HS2016, HS2032, HS2064, HS2128,
HS3032, HS3128, HS3248 alarm controllers. The module can be directly programmed from the
system keypad by entering [*][8] [Installer Code][802] followed by the associated section numbers
found in Section 4 of this manual.
Corbus Power
Corbus Ground
Corbus Com A
Corbus Com B
Auxiliary Power Output (PTC protected locally).
NOTE: Output current is limited by the available current at the panel
AUX/RED
output
Common Ground terminal for station wiring
Microphone #1 (M1) Input Channel
Microphone #2 (M2) Input Channel
Microphone #3 (M3) Input Channel
Microphone #4 (M4) Input Channel
Speaker Level Output (supports two DSC Audio Stations)
Speaker Level Output (supports two DSC Audio Stations)
NOTE: SPK1 and SPK2 are parallel wired from a single audio output. Any
combination of audio stations can be used as long as the maximum current
rating is not exceeded:
- 4 small stations (PC5961E)
- 2 large stations (PC5964E)
- 1 large & 2 small stations
Audio Out
Ground
Audio In
NOTE: This is an alternate terminal block. See Figure 4 for use.
Connected to R-1 terminal on the alarm panel
Connected to T-1 terminal on the alarm panel
Connected to house phones
Connected to house phones