5. Press the Enter key. The display will read
"M---S." Now assign the maximum time
to be allowed for reaching the fill level in
minutes and seconds.
6. Press the Enter key, and go to the next
step in the cycle.
Keys Pressed
Hot + Low + Enter
Hot + Med + Enter
Hot + High + Enter
Warm + Warm + Low + Enter
Warm + Hot + Low + Enter
Warm + Cold + Low + Enter
Cold + Low + Enter
Cold + Med + Enter
Cold + High + Enter
Hot + Overflow + Enter
Cold + Overflow + Enter
Warm + Warm + Overflow + Enter
In addition to the standard fill temperatures, computer-controlled fill or overflow to a specific temperature is available.
Programming a Supply Step–Models
with 8 Supplies
The WE-6 computer is capable of controlling
8 separate supplies, and up to 31 various
combinations of the 8 supplies. See the Supply
Display Codes table in this subsection for a
listing of the energized supply compartments
represented by each display code. The supplies
are divided into 2 separate banks of 4 supplies
each. Supply 5 acts as a switching function
between the 2 banks of supplies and is counted
as one of the 31 combinations, as it can be
programmed alone for special applications.
F232089
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
The computer will attempt to maintain the
temperature within a margin of plus or minus
5 degrees of the target fill temperature during
such a step.
Fill Temperature Programming
Display
"HL"
"HM"
"HH"
"WL"
"WL"
"WL"
"CL"
"CM"
"CH"
"HO"
"CO"
"WO"
The LED display will indicate the combination
of supply compartments that will energize for
that particular supply. For example, when a
Supply 3 (first supply bank, third supply signal)
is programmed, the display reads "S3nncc,"
with "nn" representing the step number and
"cc" representing the cycle number. Supply 3
flushes supply compartment 3. When Supply 7
(second supply bank, second supply signal) is
selected, the display reads "S7nncc." See the
Supply Designations table in this subsection for
a full explanation of the 8 available supplies.
Programming
Valves Operating
1 Hot Fill and 1 Hot Spray
1 Hot Fill and 1 Hot Spray
1 Hot Fill and 1 Hot Spray
Both Hot and Both Cold
Both Hot and 1 Cold Fill
1 Hot Fill and Both Cold
1 Cold Fill and 1 Cold Spray
1 Cold Fill and 1 Cold Spray
1 Cold Fill and 1 Cold Spray
1 Hot Fill to overflow
1 Cold Fill to overflow
Both Hot and Both Cold to overflow
41