Programming
Step Programming
It is possible to change which supply
compartments are flushed for a particular
supply. For example, a Supply 3 (first supply
bank) energizes compartment 3. Suppose
that there is a need for compartments
1 and 3 to energize instead. The following
procedure would accomplish this:
1. Advance to the supply step to be changed
(Supply 3 in this case).
2. The display will read "S3nncc."
3. Press the Clear/Stop key to clear the
programmed supply compartments to
be flushed from the WE-6 computer.
4. Press the Supply key and key 3 again.
5. The display will read "S3nncc."
6. Now press key 1 to program a flush of
compartment 1.
7. The display will read "SBnncc," with B
representing the code from the Supply
Display Codes table that corresponds to the
energizing of compartments 1 and 3.
Note: The order in which key 1 and key 3 are
pressed is not important. The computer's
interpretation of the supply compartment
combination is not dependent upon the order
of entry.
8. Press the Enter key. The display will now
read "M---S." Enter the time in minutes
and seconds that the supply injection
should last.
9. Press the Enter key and go on to the next
step in the cycle.
44
(Continued)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Supply Display Codes (8 supplies)
Supply Number
Code
1
2
A
3
B
C
D
4
E
F
H
I
J
L
M
5
6
7
N
8
O
P
Q
9
R
S
T
U
V
W
X
0 = Supply Off
X = Supply On
5 4 3 2 1
0 0 0 0 X
0 0 0 X 0
0 0 0 X X
0 0 X 0 0
0 0 X 0 X
0 0 X X 0
0 0 X X X
0 X 0 0 0
0 X 0 0 X
0 X 0 X 0
0 X 0 X X
0 X X 0 0
0 X X 0 X
0 X X X 0
0 X X X X
X 0 0 0 0
X 0 0 0 X
X 0 0 X 0
X 0 0 X X
X 0 X 0 0
X 0 X 0 X
X 0 X X 0
X 0 X X X
X X 0 0 0
X X 0 0 X
X X 0 X 0
X X 0 X X
X X X 0 0
X X X 0 X
X X X X 0
X X X X X
F232089