Programming
Step Programming
6. Wet Clean 1/2 Wash Speed (Gentle
Wash). The Wash 1, 2, 4, 5, and 6
agitations can have either normal wash
speed or 1/2 wash speed (gentle wash) if
the WE-6 is prompted for wet cleaning
("WET CL") and the necessary hardware
is installed. To select the gentle wash
speed, program an Auxiliary 1 step (A1)
before the low-speed step or steps which
are to have reduced wash speed. Any
time for the Auxiliary 1 step may be
programmed: 1 second is a good choice.
The reduced wash speed will then be in
effect until a drain step is activated or until
the stop routine takes place. The computer
accomplishes this by leaving the Auxiliary
1 output energized after an Auxiliary 1
step until a drain step is reached.
Note: If "NO WCL" is selected in the
prompting process, Auxiliary 1 operates
as a timed output (remains on for the time
programmed).
7. Recirculation Pump. The computer must
be prompted for "1DRAIN" and "WET
CL." Also, a second drain should not be
connected to the Auxiliary 2 output if the
recirculation pump is used. However, a
second independent drain will operate
properly when connected to the Auxiliary
2 output if the WE-6 is prompted for
"2DRAIN." Thus, one machine cannot
have both a recirculation pump and a
second independent drain.
52
(Continued)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Note: This is not the same as the "dual drain"
option. Dual drain models operate the two
drains simultaneously. A second independent
drain, on the other hand, can be programmed
to operate independently of the main drain
(drain 1) if "2DRAIN" is prompted. This
capability would only be used in special
applications and is not for use with standard
wet cleaning applications. Therefore, the drain
should be prompted for "1DRAIN," under
normal operating conditions.
If the WE-6 is prompted for "WET CL",
the Auxiliary 2 output remains on until a
drain step is activated or until the stop
routine is initiated. Also, the computer will
turn off the Auxiliary 2 output
(recirculation pump) upon entering
a Wash 7 step.
Note: The WE-6 precludes operation of the
recirculation pump if the temperature exceeds
160 degrees Fahrenheit (71 degrees
Centigrade) for the remainder of the step in
effect at the time.
Note: If "NO WCL" and "1DRAIN" are
selected in the prompting process, Auxiliary 2
operates as a timed output (remains on for the
time programmed).