Programming A Drain Step; Programming A Flush Step - Alliance Laundry Systems UW35PV Instrucciones Se Operacion Y Programación De La Microcomputadora

Lavadora extractora cilíndrica de montaje permanente de velocidad variable
Ocultar thumbs Ver también para UW35PV:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Press the Enter key. The display will read
"H---M." Now assign the soak step the
desired time in hours and minutes. During
the soak step, no agitation will occur. The
WE-6 microcomputer will maintain the
water level during the soak cycle at
whatever previous level was programmed.
4. Press the Enter key and go to the next
step in the cycle.

Programming a Drain Step

1. The computer must be in the PROGRAM
mode, and the cycle programming
sequence must be ready for the next step.
2. Press the Drain key. The display will
read "D-nncc."
3. Press key 1 for a regular drain to sewer or
a floor drain. The display will read
"D1nncc."
4. Press the Enter key. The display will read
"M---S." Now assign the time which will
allow the machine to drain to empty.
This is an alarm time. The machine
should drain in 30 seconds under normal
conditions. The recommended drain time
is one minute. Drain times of more than
one minute are not recommended.
5. Press the Enter key and go to the next
step in the cycle.
F232089
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming

Programming a Flush Step

When the Flush key is pressed, the drain will
remain open and the basket will rotate in slow
speed forward only. Water is added only
through the door spray nozzle.
1. The computer must be in the PROGRAM
mode, and the cycle programming
sequence must be ready for the next step.
2. Press a water temperature key, either Cold,
Hot, or Warm. If the Cold key is pressed,
for example, the display will read
"C-nncc," etc.
3. Press the Flush key. The display will read
"CFnncc," "HFnncc," or "WFnncc,"
depending upon the temperature selected.
4. Press the Enter key. The display will
read "M---S." Now assign the desired
flush time in minutes and seconds.
5. Press the Enter key and go to the next
step in the cycle.