Additional Control Input/Output Wiring
Built-In Duplex Alternator – Use the ALTERNATOR terminals to connect two drives in a lead/lag con-
1.
figuration. Refer to
munication cable should for this connection. Refer to
•
Connect the black cable lead to the A terminal on both drives.
•
Connect the red cable lead to the B terminal on both drives.
•
Connect the green cable lead to the
IMPORTANT: Both drives should be wired from the same panel to ensure proper communication and
operation.
2. Moisture Sensor – The WET SENSOR terminal supports the Franklin Electric Moisture Sensor.
•
Connect the red cable lead to the +24 terminal.
•
Connect the black cable lead to the
•
Connect the white cable lead to the I+ terminal.
•
Connect the green cable lead to the I– terminal.
Refer to
"Moisture Sensor" on page 29
"Duplex Alternator Feature" on page
terminal when applicable.
terminal.
for more information about configuring this input.
38. An appropriate Duplex Alternator com-
"Accessories" on page
49.
ELECTRICAL INSTALLATION
Control Circuit Connections
23